ART-Fi SAR SYSTEMS
PORTFOLIO
ART-MAN
FLAT
Best plan for:
+ Start a SAR business
+ Pre-cert testing
+ R&D antenna design
+ Limited budget
ART-MAN
MODULAR
Best plan for:
+ Pre-cert testing
+ R&D antenna design
+ Growing businesses
Performances
+ SAR measurement accuracy: High
+ Measurement quality: Absolute
+ Technology: 100% vector probes
+ Amplitude & phase (electric field over a surface): yes
+ 3-D field distribution: Laws of physics
Characteristics
+ Measurement speed: Real-time
+ SAR measurement accuracy: High
+ Measurement quality: Absolute
+ Technology: 100% vector probes
+ Amplitude & phase (electric field over a surface)
+ 3-D field distribution: Laws of physics
+ Dimensions (W x H x D) : 140 x 90 x 62 cm
+ Weight : 145 kg
+ System I/O : Gigabit Ethernet interface
+ Recommended calibration interval : 1 year
+ Operating frequency range : 0.69 – 6 GHz
+ Analysis bandwidth: 40 MHz
+ 1 scan = 780 E-field measurements in flat phantom
+ 570 E-field measurements in one SAM side
+ Operating frequency range : 0.69 – 6 GHz
+ Preliminary expanded uncertainty (95% confidence interval): ≤ 30%
+ Analysis bandwidth: 40 MHz
+ SAM left, right and flat phantoms shape, shell thickness & dielectric parameters: Compliant with IEC 62209 (-1/-2/-3) and IEEE 1528 requirements
+ Flat phantom dimensions: 300 x 231 mm ellipse
+ Number of sensors per SAM side: 285
+ Number of sensors per FLAT section: 390
+ Tissue dielectric parameters: compliant with IEC 62209 (-1/-2/-3) and IEEE 1528 requirements
+ FCC body tissue dielectric parameters: Meets targets from OET Bulletin 65 Supplement C 01-01 within +/-10% Compensation compliant with KDB 865664 D01
+ SAM left, right and flat phantoms shape, shell thickness & dielectric parameters: Compliant with IEC 62209 (-1/-2/-3) and IEEE 1528 requirements
+ Characteristic impedance: 50 Ohm
+ Multiplexing characteristics: 64-channel to 2-channel multiplexer Switch Technology : GaAS pHEMT
+ Downconverter: 2-channel - synchroneous superheterodyne architecture, multiple conversion 40MHz IF filters bandwidth
+ Analog to digital conversion: 16 bits, 250 MS/s digitizer, acquisition synchronized on signal bursts
+ MAX scan rate (sensor array): 100 000 cycles/s 1 cycle = 1 FFT perfomed on 1024 samples
+ CPU: Intel Core i7TM
+ Operating system: ART-Fi OS
+ FPGA processors: 2 x Xilinx Virtex - 500MHz max clock speed
+ FFT: 2-channel 16-bit 1024 samples
+ Signal averaging / probe integration: Specified for each modulation and signal type – typ. 32 cycles/probe
+ Peak spatial-average SAR calculation algorithms: Compliant with IEC 62209 (-1/-2/-3)and IEEE 1528 requirements
ART-MAN
ESSENTIAL
Performances
+ SAR measurement accuracy: High
+ Measurement quality: Absolute
+ Technology: 100% vector probes
+ Amplitude & phase (electric field over a surface): yes
+ 3-D field distribution: Laws of physics
Best plan for:
+ Pre-cert testing
+ R&D antenna design
+ High skilled SAR experts
ART-MAN
DUOBODY
Performances
+ SAR measurement accuracy: High
+ Measurement quality: Absolute
+ Technology: 100% vector probes
+ Amplitude & phase (electric field over a surface): yes
+ 3-D field distribution: Laws of physics
Best plan for:
+ International certification
+ International Pre-cert testing
+ R&D antenna design